From Mccb 4 Phase (4Pole) 40Ka Hager Rating 16A-100A Type X160 0
From Mccb 4 Phase (4Pole) 40Ka Hager Rating 16A-100A Type X160 1

Mccb 4 Phase (4Pole) 40Ka Hager Rating 16A-100A Type X160

Minimum Order 1
Country Origin Indonesia
Last Updated 02 Jan 2018
Harga
Rp 1,468,800 *harga belum termasuk PPN

Seller

PT Oscar Tunastama (www.distributorhager.com)

Verified Supplier
Address

Jl Kapuk Raya Cengkareng Blok L No. 18 Ruko Citypark

Product Details Mccb Hager 4 Phase (4Pole) 40Ka Rating 16A Type hna 017p

Mccb Function Is As The Medium Voltage Circuit Breakers.Rating 16 A Type Hna017p, Rating 20A Type Hna021p, Rating 25A Type Hna026pRating 32A Type Hna033p, Rating 40A Type Hna041a, Rating 50A Type Hna051pRating 63A Type Hna064p, Rating 80A Type Hna081p, Rating 100A Type Hna101pIn Choosing A Circuit B
Dapatkan penawaran terbaik untuk Mccb 4 Phase (4Pole) 40Ka Hager Rating 16A-100A Type X160 !
Name
Quantity
Unit
We are Online Media consists of Distributor, Reseller, Manufacture, Supplier. If you are interested to buy Mccb 4 Phase (4Pole) 40Ka Hager Rating 16A-100A Type X160 cheap, please contact the Company directly.

If you are a Company who wish to sell your product,
Product Details

Mccb Function Is As The Medium Voltage Circuit Breakers.

Rating 16 A Type Hna017p, Rating 20A Type Hna021p, Rating 25A Type Hna026p

Rating 32A Type Hna033p, Rating 40A Type Hna041a, Rating 50A Type Hna051p

Rating 63A Type Hna064p, Rating 80A Type Hna081p, Rating 100A Type Hna101p

In Choosing A Circuit Breaker Of Things That Should Be Considered Are:

The Characteristics Of The System In Which The Circuit Breaker Is Installed.
The Need For Continuity Of Service Of An Electrical Power Source.
The Rules And Standards In Force Protection.
Characteristics Of The System

1 . System Voltage
Operating Voltage Of The Circuit Breaker Must Be Greater Or Equal To The Minimum Voltage Of The System .
2 . The Frequency Of The System
Rated Frequency Of The Circuit Breaker Must Be In Accordance With The Frequency Of The System . Merlin Gerin Circuit Breakers Can Operate At A Frequency Of 50 Or 60 Hz .
3 . Rated Current
Rated Current Of The Circuit Breaker Must Be Adjusted To The Size Of The Load Current Which Is Passed By Cable , And Should Be Smaller Than The Threshold Current Is Allowed To Pass On The Cable .
4 . Breaking Capacity
Breaking Capacity Of The Circuit Breaker Shall Be At Least Equal To The Prospective Short Circuit Current Which May Occur At Any Point In The Installation Where The Circuit Breaker Is Installed .
5 . Number Of Poles Of Circuit Breaker
6 . The Number Of Poles Of The Circuit Breaker Is Dependent Upon The Grounding System Of The System .

Continuity Needs Resources

Depending On The Level Of Continuity Of Service Requirements Of Power Resources , The Selecting Circuit Breakers Must Be Considered :
1 . Discrimination Breakaer Total Of Two Circuit Placed In Series .
2 . Discrimination Is Limited ( In Part ) , Discrimination Is Only Guaranteed Up To A Certain Level Of Fault Currents .

Product Specifications Hager H3 Mccb Series Frame Type: X160

- Easy To Install
- The Setting Is Simple For Maximum Installation Efficiency
- Calibration Temperature: 50C
- Breaking Capacity: 40Ka (400/415 V Ac)
- Icu = 40Ka, Ics = 25Ka