From Yokogawa Pressure Transmitter 0

Yokogawa Pressure Transmitter

Minimum Order 1
Country Origin Japan
Last Updated 16 Jun 2016
Harga
CALL

Seller

Address

Jl. Kehakiman V No. 51 - Komplek Departemen Kehakiman Tanah Tinggi - Kodya

Product Details Pressure Transmitter YOKOGAWA EJA210A & EJA220

Model EJA210A and EJA220A Flange Mounted Differential Pressure TransmittersThe high performance flange mounted differential pressure transmitter models EJA210A and 220A can be used to measure levels of densities of solidifying or precipitating liquids. Both output a 4 to 20 mA DC signal correspondin
Dapatkan penawaran terbaik untuk Yokogawa Pressure Transmitter !
Name
Quantity
Unit
We are Online Media consists of Distributor, Reseller, Manufacture, Supplier. If you are interested to buy Yokogawa Pressure Transmitter cheap, please contact the Company directly.

If you are a Company who wish to sell your product,
Product Details

Model EJA210A and EJA220A Flange Mounted Differential Pressure Transmitters

The high performance flange mounted differential pressure transmitter models EJA210A and 220A can be used to measure levels of densities of solidifying or precipitating liquids. Both output a 4 to 20 mA DC signal corresponding to the measured differential pressure. Models EJA210A and 220A also feature remote setup and monitoring through communications with the BRAIN™ terminal and CENTUM CS™ or  XL™ or HART® 275 host

STANDARD SPECIFICATIONS
Refer to GS 01C22T02-00E for FOUNDATION Fieldbus communication type and GS 01C22T03-00E for PROFIBUS PA communication type marked with “.”


 PERFORMANCE SPECIFICATIONS
Zero-based calibrated span, linear output, wetted parts material code‘S’ for 3-inch flange flush type and 4-inch flange extended type.
Reference Accuracy of Calibrated Span (including the effects of zero-based linearity, hysteresis, and repeatability)
0.075 % of Span
 For spans below X,

[0.025 + 0.05 ] % of Span
X
Span
where X equals:
Capsule X kPa {inH2O}
M 10 {40}
H 100 {400}
Ambient Temperature Effects
Total Effects per 28 °C (50 °F) Change
Capsule Effect
M [0.224 % Span + 0.056 % URL]
H [0.14 % Span + 0.028 % URL]
Static Pressure Effects
Total Effects per Change
[0.028 % Span+0.007 % URL] per 0.69 MPa
{100 psi}
Effect on Zero (can be corrected at line pressure)
0.007 % of URL per 0.69 MPa {100 psi}
Stability
0.1 % of URL per 60 months
Power Supply Effects “”
0.005 % per Volt (from 21.6 to 32 V DC, 350 )